Model: NL-CM-7K
The problem
Many laboratories still run transient overvoltage tests on old impulse generators: nobody can prove the open circuit waveform is 1.2/50us, polarity cannot be reversed and the interval depends on hand pressing. The report says the test was done, but once a customer asks for waveform parameters the answer is missing, and retesting costs far more than the instrument.
Capability
The tester evaluates the ability of an appliance to withstand transient overvoltage. The open circuit waveform matches the 1.2/50us standard impulse defined in IEC 61180, so front time and time to half value can be verified. Output voltage is settable from 0 to 7kV, covering the usual insulation coordination levels of household appliances and OEM products. Source impedance is within 42 Ohm and the interval between impulses is at least 1s, so consecutive impulses do not stack heat into the specimen. Polarity can be reversed between positive and negative without rewiring, covering both polarities required by the standard. The high voltage terminal and the earth terminal are laid out separately with high voltage warning marking, and the output can be connected to test fingers or metal foil to check accessible parts and insulation clearances. The bench-top build runs from a normal mains supply and fits a workstation layout next to dielectric strength, insulation resistance and leakage current tests, forming a complete safety test chain.

Applicable standards
GB/T 4706.1-2024 Household and similar electrical appliances, safety, Part 1 general requirements, clause 14 transient overvoltage (current); IEC 61180 High-voltage test techniques for low-voltage equipment (1.2/50us standard impulse); GB/T 16927.1-2011 High-voltage test techniques, Part 1 general definitions and test requirements (current); test voltage and points of application follow the product standard and the customer technical agreement.
Key specifications
- Output voltage: 0 to 7kV settable
- Open circuit waveform: 1.2/50us standard impulse per IEC 61180
- Source impedance: within 42 Ohm
- Impulse interval: 1s minimum
- Polarity: positive and negative, reversible
- Test object: accessible parts and insulation clearances under transient overvoltage
- Applicable clause: GB/T 4706.1-2024 clause 14
- Construction: bench-top, high voltage and earth terminals separate
- Power: AC220V, 50Hz
Applications
Routine transient overvoltage testing in appliance and OEM safety laboratories; pre-testing and corrective verification before third-party certification; outgoing quality sampling at appliance plants; insulation coordination and component selection during development
About the manufacturer
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.