您好,欢迎来到中国企业库   [请登陆]  [免费注册]
小程序  
APP  
微信公众号  
手机版  
 [ 免责声明 ]     [ 举报 ]
客服电话:13631151688
企业库首页>机械行业>试验机>其他试验机 我也要发布信息到此页面
超级猎聘人才网 广告
Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing
Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing
Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing
Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing

Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing

Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing 相关信息由 Guangdong Endurance Electronic Equipment Co., Ltd提供。如需了解更详细的 Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing 的信息,请点击 https://www.qiyeku.cn/b2b/nailisb.html 查看 Guangdong Endurance Electronic Equipment Co., Ltd 的详细联系方式。

[手机端查看]
Mr. Wu(Manage)
0086-13416787649
立即咨询
Guangdong Endurance Electronic Equipment Co., Ltd
0086-13416787649
4th Floor, No.73 Liande Street, Gaosha Community, Xiaolan Town, Zhongshan City, Guangdong Province, China
zsnaili@163.com
[店铺小程序]

Guangdong Endurance Electronic Equipment Co., Ltd



<p>Guangdong Endurance Electronic Equipment Co., Ltd. (brand: NAILI) is a professional manufacturer of non-standard testing equipment for the home appliance industry, located in Xiaolan Town, Zhongshan City, Guangdong Province, China. The company integrates R&D, manufacturing, on-site commissioning and after-sales service.</p><p>Main products: dishwasher test equipment, dishwasher pump performance testing machine, dishwasher pump durability tester, dishwasher circuit board (PCB) tester, dishwasher solenoid valve comprehensive testing machine, washing machine durability laboratory / reliability test line, water level switch durability testing machine, water level sensor durability testing machine, and other automatic testing lines for home appliance components.</p><p>All equipment is designed according to GB/T 20290 / IEC 60436, GB 4706.25 / IEC 60335-2-5, GB 4706.24 / IEC 60335-2-7, GB/T 4288, GB 14536 / IEC 60730 and other national / international standards. The company has passed ISO 9001 quality management system certification.</p><p>Address: 4th Floor, No.73 Liande Street, Gaosha Community, Xiaolan Town, Zhongshan City, Guangdong Province, China (Zip code: 528414)  |  Tel: 0086-13416787649  |  E-mail: zsnaili@163.com  |  Website: http://en.zsnaili.com</p>
详细信息 我也要发布信息到此页面

Model: NL-FYK-2

The problem

The air pressure switch is the head safety gate of the flue-gas chain in gas water heaters and wall boilers: failing to act on blocked flue is an accident, and a drifting actuation point becomes ignition failures and warranty tickets. Incoming checks that only puff air and read continuity leave the actuation pressure, the drift after tens of thousands of cycles and the NO or NC type all undocumented, so every new supplier or batch restarts the risk.

Capability

The bench serves performance testing and endurance life testing of air pressure switches of all models used in gas appliances. Two stations run endurance tests at the same time, each controlled independently. A gas booster produces 0 to 1MPa output from a 5 to 15MPa nitrogen source supplied by the customer, regulated by PID or manually for a stable and reliable supply. Pneumatic output spans 0.1Pa to 1MPa in positive pressure with plus or minus 1 percent accuracy, covering both the millipascal actuation range and the high-pressure proof range. The circuit follows the standard sequence automatically: the PLC drives the main regulating solenoid valve to set the output pressure, a stabiliser and back-pressure valve split and steady the flow delivered to the specimen, and after the specimen actuates the flow returns through the water pipe to the venting solenoid valve for depressurisation. Test rate is 15 to 50 cycles per min, on-off time 1 to 999s and count range 0 to 99999999, stopping automatically at the set count. During the test the bench detects automatically whether the switch is normally open or normally closed. One endurance cycle counts once; a faulty switch stops only its own station with an audible and visual notice while the other keeps running. Test data survive power loss. Control is a Xinje PLC with touch screen, and fixtures include a 7/16-20 internal-thread tooling clamp and a 6.35mm copper-tube sealing clamp, with NMB or equivalent high-pressure solenoid valves.

NL test equipment

NL test equipment

Applicable standards

GB/T 14536.7-2024 Automatic electrical controls, Part 7 Particular requirements for automatic electrical pressure sensing controls including mechanical requirements (current, effective 2025-05-01, identical to IEC 60730-2-6:2015, replacing GB/T 14536.7-2010); GB/T 14536.1-2022 Part 1 General requirements; appliance references GB 6932-2015 domestic gas instantaneous water heaters and GB 25034-2020 gas heating and hot water combi boilers; actuation points, cycles and judgement follow the customer technical agreement or product drawing.

Key specifications

  • Stations: 2, independently controlled, simultaneous endurance testing
  • Pneumatic output: 0.1Pa to 1MPa (gas booster, positive pressure)
  • Pressure accuracy: plus or minus 1 percent
  • Gas source: 5 to 15MPa nitrogen (customer supplied), PID or manual regulation
  • Pneumatic path: regulating valve - stabiliser and back-pressure valve - specimen - return pipe - venting valve
  • Test rate: 15 to 50 cycles per min
  • On-off time: 1 to 999s adjustable
  • Count range: 0 to 99999999, automatic stop at set count
  • Type detection: automatic NO / NC recognition
  • Fault handling: faulty station stops with audible and visual notice, other station continues
  • Data: power-loss memory, touch screen digital display
  • Control: Xinje PLC plus touch screen
  • Fixtures: 7/16-20 internal-thread clamp; 6.35mm copper-tube sealing clamp
  • High-pressure solenoid valves: NMB or equivalent

Applications

Batch inspection and type testing at air pressure switch factories; incoming inspection at gas water heater and wall-hung boiler plants; actuation and endurance verification in third-party laboratories; comparison after supplier or diaphragm changes

About the manufacturer

Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.

郑重声明:产品 【Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing】由 Guangdong Endurance Electronic Equipment Co., Ltd 发布,版权归原作者及其所在单位,其原创性以及文中陈述文字和内容未经(企业库www.qiyeku.cn)证实,请读者仅作参考,并请自行核实相关内容。若本文有侵犯到您的版权, 请你提供相关证明及申请并与我们联系(qiyeku # qq.com)或【在线投诉】,我们审核后将会尽快处理。
会员咨询QQ群:902340051 入群验证:企业库会员咨询.
类似产品
Central Sensor Diaphragm Endurance Test Machine NL-ZXCG-2 Two Stations Stepper Press-Hold-Release Automatic Cycle 0-5000N Force Monitoring Over 20000N Capacity 1-10 Cycles per Min 999999 Counts GB/T 14536.7-2024 Electric Pressure Cooker Sensor Testing
Central Sensor Diaphragm Endurance Test Machine NL-ZXCG-2 Two Stations Stepper Press-Hold-Release Automatic Cycle 0-5000N Force Monitoring Over 20000N Capacity 1-10 Cycles per Min 999999 Counts GB/T 14536.7-2024 Electric Pressure Cooker Sensor Testing
Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing
Air Pressure Switch Endurance Test Bench NL-FYK-2 Two Stations 0.1Pa to 1MPa Wide Range NO-NC Auto Detection 15-50 Cycles per Min Nitrogen PID 99999999 Counts GB/T 14536.7-2024 Gas Water Heater Wall Boiler Pressure Switch Testing
Solar Simulation Test Equipment NL-RGZ-1500 400-1500W/m2 AM1.5G Class A Dual 1m2 Matrix Independent Angle 0-2m Lift Plus or Minus 2 Percent Uniformity Refrigerant Leak Interlock AC Solar Load Testing
Solar Simulation Test Equipment NL-RGZ-1500 400-1500W/m2 AM1.5G Class A Dual 1m2 Matrix Independent Angle 0-2m Lift Plus or Minus 2 Percent Uniformity Refrigerant Leak Interlock AC Solar Load Testing
Pressure Cooker Safety Device Non-Reset Test Bench NL-FWF-1 Six Pressure Tests Working Safety Heat Resistance Internal Pressure Relief Burst GB 13623 GB 15066 Pressure Curve Recording
Pressure Cooker Safety Device Non-Reset Test Bench NL-FWF-1 Six Pressure Tests Working Safety Heat Resistance Internal Pressure Relief Burst GB 13623 GB 15066 Pressure Curve Recording
Incoming Solenoid Valve Performance and Life Test Bench NL-DCF-8 Eight Stations One Performance Plus Seven Life 1.75MPa Proof 0.03 and 0.84MPa Seal Flow 30000 Cycles Washer Dishwasher Inlet Valve IQC
Incoming Solenoid Valve Performance and Life Test Bench NL-DCF-8 Eight Stations One Performance Plus Seven Life 1.75MPa Proof 0.03 and 0.84MPa Seal Flow 30000 Cycles Washer Dishwasher Inlet Valve IQC
Coating Scratch Tester NL-HGH-1 ISO 12137-2 ISO 1518 Steel Tip Pencil Eraser Solvent Four Modes X0-180mm Y0-200mm 0-100mm/s 999999 Cycles 60 Degree Angle 10N Scratch Force Printed Coatings
Coating Scratch Tester NL-HGH-1 ISO 12137-2 ISO 1518 Steel Tip Pencil Eraser Solvent Four Modes X0-180mm Y0-200mm 0-100mm/s 999999 Cycles 60 Degree Angle 10N Scratch Force Printed Coatings
PET Polyester PCT Tester NL-PCT400 Saturated Steam 105-132C 100%RH Pressure 0.2-2.0kg/cm2 Safety 3.5kg/cm2 0-999 Hours 400x500mm SUS304 Chamber Highly Accelerated Aging
PET Polyester PCT Tester NL-PCT400 Saturated Steam 105-132C 100%RH Pressure 0.2-2.0kg/cm2 Safety 3.5kg/cm2 0-999 Hours 400x500mm SUS304 Chamber Highly Accelerated Aging
Incoming Thermostat Performance Tester NL-WKQ-28 28 Stations Snap-Action and Liquid-Expansion Types GB/T 14536.10 40-200C System Accuracy 0.2C 0.1C Per Min At Action Point Auto Judgement Statistics Printing
Incoming Thermostat Performance Tester NL-WKQ-28 28 Stations Snap-Action and Liquid-Expansion Types GB/T 14536.10 40-200C System Accuracy 0.2C 0.1C Per Min At Action Point Auto Judgement Statistics Printing