The problem
Appliances charged with R290, R32 or R600a must be tested against simulated leakage scenarios under the standard. Without a controlled leakage-test environment - where leak points can be placed, concentration sampled and ventilation verified - the test is neither repeatable nor safe, and certification queues simply lengthen.
Capability
The room is built as one line: enclosure - leak - sampling - interlock. The enclosure is sealed and ventilated to the standard clauses, and simulated leak points are placed along the sample refrigerant circuit and adjusted per model. After release, flammable-refrigerant concentration probes sample continuously, so the concentration distribution and dilution process are fully recorded. Flammable gas detection, alarm devices and forced ventilation are interlocked: any point over limit trips the ventilation and the test stays under control throughout. Air-conditioning units (R290/R32/R1270) and refrigerator units (R600a) share one room; changing model only means repositioning leak points and sampling, with no second construction. Enclosure, sampling lines, ventilation and electrics are delivered complete as a turnkey project.

Applicable standards
Built to GB 4706.32-2012 Safety of household and similar electrical appliances - Particular requirements for heat pumps, air-conditioners and dehumidifiers, clauses 22.107, 22.108 and 22.109, and the corresponding clauses of GB 4706.13-2014 for refrigerating appliances; refrigerant, sampling and ventilation parameters follow the sample specification.
Key specifications
- Refrigerants: R290 / R32 / R1270 (air-conditioning) and R600a (refrigeration) flammable refrigerants
- Basis: GB 4706.32-2012 clauses 22.107-22.109; GB 4706.13-2014 corresponding clauses
- Samples: air-conditioners / heat pumps / dehumidifiers / refrigerators on flammable refrigerants
- Leak simulation: leak points placed per standard clauses, adjustable per sample model
- Concentration: continuous sampling and recording of flammable refrigerant concentration
- Safety package: flammable gas detection + alarm device + ventilation safety interlock
- Delivery: enclosure + sampling lines + ventilation + electrics, designed to the sample specification
Applications
Flammable-refrigerant safety rooms at air-conditioner and refrigerator plants; structural safety verification and certification support for R290/R32/R600a models; capability extension for third-party laboratories
About the manufacturer
Guangdong Endurance Electronic Equipment Co., Ltd provides non-standard customization, drawing confirmation, factory acceptance, on-site installation and commissioning, operation training and long-term technical service; 12-month warranty and long-term spare parts supply. Tel: 0760-88500902 / 13416787649. Web: en.zsnaili.com.